Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/1568
DC FieldValueLanguage
dc.contributor.authorPerry, Gilbert J.en
dc.contributor.authorGreen, Derek W.en
dc.contributor.authorAnayiotos, Andreas-
dc.contributor.otherΑναγιωτός, Ανδρέας-
dc.date.accessioned2013-03-04T13:21:22Zen
dc.date.accessioned2013-05-17T05:22:22Z-
dc.date.accessioned2015-12-02T10:00:21Z-
dc.date.available2013-03-04T13:21:22Zen
dc.date.available2013-05-17T05:22:22Z-
dc.date.available2015-12-02T10:00:21Z-
dc.date.issued1996en
dc.identifier.citationUltrasound in Medicine and Biology, 1996, Volume 22, Issue 5, Pages 605-621en
dc.identifier.issn03015629en
dc.identifier.urihttps://hdl.handle.net/20.500.14279/1568-
dc.description.abstractColor Doppler is routinely used in estimates of valvular regurgitation. Velocity and subsequently flow measurements are made at about 7-10 cm from the ultrasonic transducer. Error in velocity measurement may occur due to spatial broadening of the color Doppler beam in the axial, azimuthal and lateral directions. Error in velocity may also occur due to wall filters since the filtering process is not uniform throughout the velocity range indicated by the color bar. An attempt to estimate this error was made using an in vitro orifice model, a numerical finite element model (FEM), and information from the manufacturer. We found that the acoustic beam spatial expansion, wall filter sensitivity and Nyquist limit (NYL) have to be considered simultaneously to account for errors. The combined spatial expansion and wall filter effect on velocity was estimated as a weighted average over the sample volume. The error distributions are not universal but depend on orifice size and flow. For a 3-mm orifice and 100 cm s NYL the overall effect was overestimation of low velocities and significant underestimation of high velocities due to the high velocity gradients inside the sample volume. For the 5- and the 10-mm orifice the effect was less accentuated. Based on this overall error distribution, a correction was incorporated on color Doppler obtained data. The incorporated correction yielded better agreement with numerical velocity data. This correction is important in the application of the proximal isovelocity surface area (PISA) technique and the evaluation of regurgitant flowrates. Color Doppler is routinely used in estimates of valvular regurgitation. Velocity and subsequently flow measurements are made at about 7-10 cm from the ultrasonic transducer. Error in velocity measurement may occur due to spatial broadening of the color Doppler beam in the axial, azimuthal and lateral directions. Error in velocity may also occur due to wall filters since the filtering process is not uniform throughout the velocity range indicated by the color bar. An attempt to estimate this error was made using an in vitro orifice model, a numerical finite element model (FEM), and information from the manufacturer. We found that the acoustic beam spatial expansion, wall filter sensitivity and Nyquist limit (NYL) have to be considered simultaneously to account for errors. The combined spatial expansion and wall filter effect on velocity was estimated as a weighted average over the sample volume. The error distributions are not universal but depend on orifice size and flow. For a 3-mm orifice and 100 cm s NYL the overall effect was overestimation of low velocities and significant underestimation of high velocities due to the high velocity gradients inside the sample volume. For the 5- and the 10-mm orifice the effect was less accentuated. Based on this overall error distribution, a correction was incorporated on color Doppler obtained data. The incorporated correction yielded better agreement with numerical velocity data. This correction is important in the application of the proximal isovelocity surface area (PISA) technique and the evaluation of regurgitant flowrates.en
dc.formatpdfen
dc.language.isoenen
dc.rights© 1996 World Federation for Ultrasound in Medicine & Biologyen
dc.subjectHemodynamicsen
dc.subjectEchocardiographyen
dc.subjectCardiologyen
dc.subjectDoppler effecten
dc.subjectMitral valve insufficiencyen
dc.titleAccuracy of color doppler velocity in the flow field proximal to a regurgitant orifice: implications for color doppler quantitation of valvular incompetenceen
dc.typeArticleen
dc.affiliationUniversity of Alabama at Birminghamen
dc.identifier.doihttp://dx.doi.org/10.1016/0301-5629(96)00029-4en
dc.dept.handle123456789/54en
item.openairetypearticle-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
item.languageiso639-1en-
crisitem.author.deptDepartment of Mechanical Engineering and Materials Science and Engineering-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.orcid0000-0003-4471-7604-
crisitem.author.parentorgFaculty of Engineering and Technology-
Appears in Collections:Άρθρα/Articles
CORE Recommender
Show simple item record

SCOPUSTM   
Citations 5

17
checked on Feb 13, 2018

Page view(s) 5

567
Last Week
0
Last month
1
checked on Feb 2, 2025

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.