Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.14279/1512
Title: | Dealing with imperfection:quantifying potential length scale artefacts from nominally spherical indenter probes | Authors: | Constantinides, Georgios Silva, Emilio C C M Blackman, Gregory S. |
metadata.dc.contributor.other: | Κωνσταντινίδης, Γιώργος | Major Field of Science: | Engineering and Technology | Keywords: | Approximation theory;Atomic force microscopy;Scanning electron microscopy;Methodology;Molecular probes | Issue Date: | 29-Jun-2007 | Source: | Nanotechnology, 2007, vol.18, no. 30 | Volume: | 18 | Issue: | 30 | Journal: | Nanotechnology | Abstract: | Instrumented nanoindenters are commonly employed to extract elastic, plastic or time-dependent mechanical properties of the indented material surface. In several important cases, accurate determination of the indenter probe radii is essential for the proper analytical interpretation of the experimental response, and it cannot be circumvented by an experimentally determined expression for the contact area as a function of depth. Current approaches quantify the indenter probe radii via inference from a series of indents on a material with known elastic modulus (e.g., fused quartz) or through the fitting of two-dimensional projected images acquired via atomic force microscopy (AFM) or scanning electron microscopy (SEM) images. Here, we propose a more robust methodology, based on concepts of differential geometry, for the accurate determination of three-dimensional indenter probe geometry. The methodology is presented and demonstrated for four conospherical indenters with probe radii of the order of 1-10 μm. The deviation of extracted radii with manufacturer specifications is emphasized and the limits of spherical approximations are presented. All four probes deviate from the assumed spherical geometry, such that the effective radii are not independent of distance from the probe apex. Significant errors in interpretation of material behaviour will result if this deviation is unaccounted for during the analysis of indentation load-depth responses obtained from material surfaces of interest, including observation of an artificial length scale that could be misinterpreted as an effect attributable to material length scales less than tens of nanometres in size or extent. | URI: | https://hdl.handle.net/20.500.14279/1512 | ISSN: | 13616528 | DOI: | 10.1088/0957-4484/18/30/305503 | Rights: | © IOP | Type: | Article | Affiliation: | Massachusetts Institute of Technology | Affiliation : | Massachusetts Institute of Technology | Publication Type: | Peer Reviewed |
Appears in Collections: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
24
checked on Nov 9, 2023
WEB OF SCIENCETM
Citations
25
Last Week
0
0
Last month
0
0
checked on Oct 29, 2023
Page view(s)
458
Last Week
0
0
Last month
2
2
checked on Dec 23, 2024
Google ScholarTM
Check
Altmetric
Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.