Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/14163
DC FieldValueLanguage
dc.contributor.authorChrysostomou, Christis-
dc.contributor.authorKyriakides, Nicholas-
dc.contributor.authorPittas, Michael-
dc.date.accessioned2019-06-28T08:13:36Z-
dc.date.available2019-06-28T08:13:36Z-
dc.date.issued2010-05-12-
dc.identifier.citation3rd International fib Congress and Exhibition, Incorporating the PCI Annual Convention and Bridge Conference 2010, Gaylord National Resort and Conference CenterWashington, United States, 29 May 2010 through 2 June 2010en_US
dc.identifier.isbn9780937040904-
dc.description3rd International fib Congress and Exhibition, Incorporating the PCI Annual Convention and Bridge Conference: Think Globally, Build Locally, Proceedings 2010en_US
dc.description.abstractA building that was designed, detailed and constructed in 1960 in Cyprus for gravity loads only was selected as a case-study for a pilot application of Eurocode 8 part 3. The information collected, the assessment and the retrofit of the structure are described here. It can be concluded that: 1) EC8 part 3 is a workable code that can guide the engineer through the assessment and retrofit process, 2) the knowledge level factor does not affect the capacities of ductile elements but it changes significantly those of brittle elements; for this building it may not be cost-effective to try to move from knowledge level 2 to knowledge level 3, 3) The nonlinear static method, provided it can be applied, gives a quantitative insight in the assessment and retrofit process, 4) A dedicated software is required for the application of the code, due to the considerable amount of calculations needed in determining the deformations of all the members and comparing them to the deformation capacities and 5) this code can be used for the assessment of individual buildings but it would be very costly to use it for the screening of a large number of buildings.en_US
dc.formatpdfen_US
dc.language.isoenen_US
dc.subjectEC8 part 3en_US
dc.subjectSeismic performance assessmenten_US
dc.subjectSeismic retrofittingen_US
dc.titleRetrofitting of an existing RC structure using EC8 - Part 3en_US
dc.typeConference Papersen_US
dc.collaborationCyprus University of Technologyen_US
dc.collaborationM. Pittas Engineering Consultantsen_US
dc.subject.categoryCivil Engineeringen_US
dc.countryCyprusen_US
dc.subject.fieldEngineering and Technologyen_US
dc.publicationPeer Revieweden_US
dc.relation.conferenceInternational fib Congress and Exhibitionen_US
dc.identifier.scopus2-s2.0-85013942145-
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/85013942145-
cut.common.academicyear2009-2010en_US
item.openairetypeconferenceObject-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_c94f-
item.languageiso639-1en-
crisitem.author.deptDepartment of Civil Engineering and Geomatics-
crisitem.author.deptDepartment of Civil Engineering and Geomatics-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.orcid0000-0002-7141-7423-
crisitem.author.orcid0000-0002-8956-7155-
crisitem.author.parentorgFaculty of Engineering and Technology-
crisitem.author.parentorgFaculty of Engineering and Technology-
Appears in Collections:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation
CORE Recommender
Show simple item record

Page view(s)

344
Last Week
2
Last month
3
checked on Jan 30, 2025

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.