Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.14279/14160
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chrysostomou, Christis | - |
dc.contributor.author | Kyriakides, Nicholas | - |
dc.contributor.author | Poljanšek, Martin | - |
dc.contributor.author | Taucer, Fabio | - |
dc.date.accessioned | 2019-06-28T06:59:13Z | - |
dc.date.available | 2019-06-28T06:59:13Z | - |
dc.date.issued | 2013-01-01 | - |
dc.identifier.citation | Fib Symposium, TEL-AVIV 2013,Dan Panorama HotelTel-Aviv, Israel, 22 April 2013 through 24 April 2013 | en_US |
dc.identifier.isbn | 9789659203901 | - |
dc.identifier.uri | https://hdl.handle.net/20.500.14279/14160 | - |
dc.description | Fib Symposium TEL-AVIV 2013: Engineering a Concrete Future: Technology, Modeling and Construction, Proceedings 2013, Pages 517-520 | en_US |
dc.description.abstract | The effectiveness of seismic retrofitting of multi-storey multi-bay RC-frame buildings by converting selected bays into new walls through infilling with reinforced concrete (RC) was studied experimentally at the ELSA facility of the Joint Research Centre in Ispra (Italy). A full-scale model was tested with the pseudo-dynamic method and consisted of two four-storey (12m tall) three-bay (8.5m long) parallel frames linked through 0.15m slabs with the central bay (2.5m) infilled with a RC wall. The frames were designed and detailed for gravity loads only and are typical of similar frames built in Cyprus in the 1970's. Different connection details and reinforcement percentages for the two infilled frames were used in order to study their effects in determining structural response. The results of the pseudo-dynamic and cyclic tests performed on the specimen and their analytical simulation are presented, and conclusions are drawn. | en_US |
dc.language.iso | en | en_US |
dc.subject | Full-scale pseudo-dynamic testing | en_US |
dc.subject | RC infill walls | en_US |
dc.subject | Retrofitting existing structures | en_US |
dc.title | Strengthening proposal and anal ytical simulation of the pseudo-dynamic test-response of a full-scale rc infilled model of an existing rc structure | en_US |
dc.type | Conference Papers | en_US |
dc.collaboration | Cyprus University of Technology | en_US |
dc.collaboration | European Commission | en_US |
dc.subject.category | Civil Engineering | en_US |
dc.country | Cyprus | en_US |
dc.country | Italy | en_US |
dc.subject.field | Engineering and Technology | en_US |
dc.publication | Peer Reviewed | en_US |
dc.relation.conference | Fib Symposium | en_US |
dc.identifier.scopus | 2-s2.0-85015641943 | - |
dc.identifier.url | https://api.elsevier.com/content/abstract/scopus_id/85015641943 | - |
cut.common.academicyear | 2012-2013 | en_US |
item.grantfulltext | none | - |
item.openairecristype | http://purl.org/coar/resource_type/c_c94f | - |
item.fulltext | No Fulltext | - |
item.languageiso639-1 | en | - |
item.cerifentitytype | Publications | - |
item.openairetype | conferenceObject | - |
crisitem.author.dept | Department of Civil Engineering and Geomatics | - |
crisitem.author.dept | Department of Civil Engineering and Geomatics | - |
crisitem.author.faculty | Faculty of Engineering and Technology | - |
crisitem.author.faculty | Faculty of Engineering and Technology | - |
crisitem.author.orcid | 0000-0002-7141-7423 | - |
crisitem.author.orcid | 0000-0002-8956-7155 | - |
crisitem.author.parentorg | Faculty of Engineering and Technology | - |
crisitem.author.parentorg | Faculty of Engineering and Technology | - |
Appears in Collections: | Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation |
CORE Recommender
Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.