Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.14279/13614
Title: | Building façade integrated solar thermal collectors for air heating: experimentation, modelling and applications | Authors: | Agathokleous, Rafaela Barone, Giovanni Buonomano, Annamaria Forzano, Cesare Kalogirou, Soteris A. Palombo, Adolfo |
Major Field of Science: | Engineering and Technology | Field Category: | Environmental Engineering | Keywords: | Air collector;Building integrated solar thermal systems;Dynamic energy performance analysis;Experimental validation;Low-cost materials | Issue Date: | Apr-2019 | Source: | Applied Energy, 2019, vol. 239, pp. 658-679 | Volume: | 239 | Start page: | 658 | End page: | 679 | Journal: | Applied Energy | Abstract: | In this paper the design and the energy performance investigation of a new flat-plate solar thermal air collector prototype is presented. The adoption of cost-effective materials and simple design solutions represent the main novelties of the proposed device when compared to existing commercial collectors. In addition, the prototype is suitably designed to be integrated into the building envelope (façade), which is a key feature for the market uptake of building integrated solar thermal systems. The paper includes the description of the dynamic simulation model, developed for the energy and economic performance analyses of the whole building-prototype system. The simulation model, implemented with a computer code written in MatLab, is able to predict both active (hot air production for building space heating) and passive (winter free heating and summer overheating) effects due to the building integration of the proposed solar collector. By such tool, indoor comfort investigations can also be carried out. The dynamic simulation models of both the building and the collector prototype were successfully validated. In order to show the features of the developed simulation code, a suitable case study was carried out. It refers to an office space, part of a high-rise multi-use building, simulated as located in three different weather zones (Freiburg, Naples and Almeria). The examined solar collector is modelled as vertically integrated into the building façade, and three different orientations (East, South-East and South) were taken into account. Interesting results for the energetic, economic and occupants comfort points of view are obtained. By taking into account an initial cost of the system of about 5 k€ the primary energy savings achieved by the proposed system against the traditional buildings range between 1.9 and 8.0 MWh/y (depending on the selected weather zone and backup system). The shortest payback for all the investigated weather zones is obtained for Naples, which is equal to 6.2 years. | ISSN: | 03062619 | DOI: | 10.1016/j.apenergy.2019.01.020 | Rights: | © Elsevier | Type: | Article | Affiliation : | University of Naples Federico II Concordia University Free University of Bozen-Bolzano Cyprus University of Technology |
Publication Type: | Peer Reviewed |
Appears in Collections: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
61
checked on Nov 6, 2023
WEB OF SCIENCETM
Citations
51
Last Week
0
0
Last month
1
1
checked on Oct 29, 2023
Page view(s)
388
Last Week
2
2
Last month
1
1
checked on Nov 24, 2024
Google ScholarTM
Check
Altmetric
Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.