Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/1315
Title: Thermosiphon solar domestic water heating systems: long-term performance prediction using artificial neural networks
Authors: Kalogirou, Soteris A. 
Panteliou, Sofia 
metadata.dc.contributor.other: Καλογήρου, Σωτήρης Α.
Major Field of Science: Engineering and Technology
Keywords: Artificial Neural Networks (ANN)
Issue Date: 2000
Source: Solar Energy, 2000, vol. 69, no. 2, pp. 163-174
Volume: 69
Issue: 2
Start page: 163
End page: 174
Journal: Solar Energy 
Abstract: The objective of this work is to use artificial neural networks (ANN) for the long-term performance prediction of thermosiphonic type solar domestic water heating (SDWH) systems. Thirty SDWH systems have been tested and modelled according to the procedures outlined in the standard ISO 9459-2 at three locations in Greece. From these, data from 27 of the systems were used for training and testing the network while data from the remaining three were used for validation. Two ANNs have been trained using the monthly data produced by the modeling program supplied with the standard ISO 9459-2. Different networks were used depending on the nature of the required output, which is different in each case. The first network was trained to estimate the solar energy output of the system for a draw-off quantity equal to the storage tank capacity (at the end of the solar energy collection period) and the second one was trained to estimate the solar energy output of the system and the average quantity of hot water per month at demand temperatures of 35 and 40°C. The collector areas of the considered systems were varying between 1.81 m2 and 4.38 m2. Open and closed thermosiphonic systems have been considered both with horizontal and vertical storage tanks. In this way the networks were trained to accept and handle a number of unusual cases. The input data in both networks are similar to the ones used in the program supplied with the standard. These were the size and performance characteristics of each system and various climatic data. In the second network the demand temperature was also used as input. For the first network the statistical coefficient of multiple determination (R2-value) obtained for the training data set was equal to 0.9993. For the second network the R2-value for the two output parameters was equal to 0.9848 and 0.9926, respectively. Unknown data were subsequently used to investigate the accuracy of prediction and R2-values equal to 0.9913 for the first network and 0.9733 and 0.9940 for the second were obtained. These results indicate that the proposed method can successfully be used for the prediction of the solar energy output of the system for a draw-off equal to the volume of the storage tank or for the solar energy output of the system and the average quantity of the hot water per month for the two demand water temperatures considered.
URI: https://hdl.handle.net/20.500.14279/1315
ISSN: 0038092X
DOI: 10.1016/S0038-092X(00)00058-X
Rights: © Elsevier
Type: Article
Affiliation : Higher Technical Institute Cyprus 
University of Patras 
Publication Type: Peer Reviewed
Appears in Collections:Άρθρα/Articles

CORE Recommender
Show full item record

SCOPUSTM   
Citations

70
checked on Nov 9, 2023

WEB OF SCIENCETM
Citations

56
Last Week
0
Last month
0
checked on Oct 28, 2023

Page view(s)

498
Last Week
0
Last month
1
checked on Nov 21, 2024

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons