dc.description.abstractThe purpose of this two-part study is to present the experimental analysis carried out on a naturally ventilated Building Integrated Photovoltaic (BIPV) system and the new correlations developed for the estimation of the convective heat transfer coefficients (CHTC) in the air gap, and use the developed correlations to construct a simulation model which is validated with the experimental data. In BIPV systems the air gap is responsible to cool the PVs and remove excess heat to avoid building overheating. The ventilation of the air gap can be natural or mechanical. However, naturally ventilated systems are less studied although they have important advantages over the mechanically ventilated ones, such as the avoidance of extra energy of the fans, maintenance and noise. The present Part I of this study presents an experimental based thermal analysis of a naturally ventilated vertical BIPV system. A series of experiments on a custom made BIPV system were carried in real outdoor conditions as well as indoors with the use of a large scale solar simulator to measure the thermal characteristics of the system and its thermal behaviour. Indoor experiments were performed to avoid external disturbances from wind that may occur outside. The results show that an open-ended air gap of 0.1 m can create adequate air flow on naturally ventilated systems and can ensure low PV temperatures to avoid PV efficiency decrease. The experimental data are then used to estimate the convective heat transfer coefficients to fit the real conditions of the BIPV systems. Then two correlations are proposed for the estimation of the Nusselt number that fits best the thermal characteristics of a naturally ventilated BIPV system.en_US
dc.formatpdfen_US
dc.language.isoenen_US
dc.relation.ispartofSolar Energyen_US
dc.rights© Elsevieren_US
dc.subjectBIPVen_US
dc.subjectNatural ventilationen_US
dc.subjectPhotovoltaicsen_US
dc.subjectThermal behaviouren_US
dc.titlePart I: Thermal analysis of naturally ventilated BIPV system: Experimental investigation and convective heat transfer coefficients estimationen_US
dc.typeArticleen_US
dc.collaborationCyprus University of Technologyen_US
dc.subject.categoryEnvironmental Engineeringen_US
dc.journalsHybrid Open Accessen_US
dc.countryCyprusen_US
dc.subject.fieldEngineering and Technologyen_US
dc.publicationPeer Revieweden_US
dc.identifier.doi10.1016/j.solener.2018.02.048en_US
dc.relation.volume169en_US
cut.common.academicyear2017-2018en_US
dc.identifier.spage673en_US
dc.identifier.epage681en_US
item.fulltextNo Fulltext-
item.cerifentitytypePublications-
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
item.openairetypearticle-
item.languageiso639-1en-
crisitem.journal.journalissn0038-092X-
crisitem.journal.publisherElsevier-
crisitem.author.deptDepartment of Mechanical Engineering and Materials Science and Engineering-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.orcid0000-0002-4497-0602-
crisitem.author.parentorgFaculty of Engineering and Technology-
Appears in Collections:Άρθρα/Articles
CORE Recommender
Show simple item record

SCOPUSTM   
Citations

34
checked on Nov 9, 2023

WEB OF SCIENCETM
Citations

25
Last Week
0
Last month
0
checked on Jul 4, 2023

Page view(s) 50

369
Last Week
4
Last month
10
checked on May 11, 2024

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.