Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/10075
Τίτλος: | Multi-storey structures with seismic isolation at storey-levels | Συγγραφείς: | Phocas, Marios Pamboris, George |
metadata.dc.contributor.other: | Παμπόρης, Γεώργιος | Major Field of Science: | Engineering and Technology | Field Category: | Civil Engineering | Λέξεις-κλειδιά: | Structural control;Seismic isolation;Seismic performance | Ημερομηνία Έκδοσης: | 1-Ιαν-2017 | Πηγή: | Computational Methods in Applied Sciences, 2017, Volume 44, Pages 261-284 | DOI: | 10.1007/978-3-319-47798-5_9 | Περίληψη: | Through increasing international research and application activities in the last years, seismic isolation has proven to be an innovative passive control technique in the area of performance-based design of buildings. Seismic isolation is principally based on the incorporation of flexible isolators at the base of low-rise buildings in order to shift the fundamental period outside of the dangerous for resonance, range of periods. In extending the concept of base isolation, the present contribution refers to the control of multi-storey structures under earthquake actions by means of introducing seismic isolation at different elevations of the structure. Thus, the structural response is influenced decisively by the vertically distributed seismic isolation, which at the respective storey-levels is alone capable of controlling the partial and overall stiffness, the force transmission and the energy dissipation process of the respective dynamic adaptable system. During strong earthquakes the effectiveness of the system in further enlarging the period of the building, compared to the classical method of seismic isolation at a unique level, is achieved, most often with decreased inter-storey deflections, and without introducing extensive displacements at the building base, which are often limited by practical constraints. The effectiveness of the proposed control system is investigated in parametric studies, in the time-history range, for a 6-storey building under ten selected earthquakes of the Greek-Mediterranean region, scaled to a maximum ground acceleration of 0.25 g. Most effective vertical distribution of seismic isolation at various storey-levels is proposed, based on the earthquake, structural and isolation characteristics used in the numerical study. | URI: | https://hdl.handle.net/20.500.14279/10075 | ISBN: | 978-3-319-47796-1 | Rights: | © Springer International Publishing AG 2017. | Type: | Book Chapter | Affiliation: | University of Cyprus Cyprus University of Technology |
Εμφανίζεται στις συλλογές: | Κεφάλαια βιβλίων/Book chapters |
CORE Recommender
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα