Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/1681
Τίτλος: Morphological evaluation of a regurgitant orifice by 3-D echocardiography: applications in the quantification of valvular regurgitation
Συγγραφείς: Smith, Barry K. 
Kolda, Michal 
Anayiotos, Andreas 
metadata.dc.contributor.other: Αναγιωτός, Ανδρέας
Λέξεις-κλειδιά: Echocardiography;Doppler ultrasonography;Hemodynamics;Cardiovascular system
Ημερομηνία Έκδοσης: 1999
Πηγή: Ultrasound in Medicine and Biology, 1999, Volume 25, Issue 2, Pages 209-223
Περίληψη: The clinical evaluation of blood flow regurgitation through a heart valve or stenotic lesion is an unresolved problem. The proximal flowfield region has been the study focus in the last few years; however, investigators have failed to identify an accurate and reliable calculation scheme due to lack of geometric information about the shape and size of the regurgitating or stenotic orifice. Presented here is a superior method of calculation, by using three-dimensional (3-D) echocardiography combined with Doppler velocimetry. The geometric structure of the orifice in a regurgitating porcine prosthetic valve in vitro was formulated by 3-D image construction of sequentially obtained 2-D images. The velocity flowfield was accessed by color Doppler flow mapping (CD) and continuous-wave Doppler (CW). Two accurate methods of calculation of regurgitant variables were developed. The first method calculated peak regurgitant flow rate from CD and the second method calculated regurgitant flow volume from CW. Both methods showed excellent correlation with the corresponding true values from an electromagnetic flowmeter. The promising preliminary results in such a realistic porcine model indicate the possibility of establishing a routine procedure to be tested in the clinical setting. The clinical evaluation of blood flow regurgitation through a heart valve or stenotic lesion is an unresolved problem. The proximal flowfield region has been the study focus in the last few years; however, investigators have failed to identify an accurate and reliable calculation scheme due to lack of geometric information about the shape and size of the regurgitating or stenotic orifice. Presented here is a superior method of calculation, by using three-dimensional (3-D) echocardiography combined with Doppler velocimetry. The geometric structure of the orifice in a regurgitating porcine prosthetic valve in vitro was formulated by 3-D image construction of sequentially obtained 2-D images. The velocity flowfield was accessed by color Doppler flow mapping (CD) and continuous-wave Doppler (CW). Two accurate methods of calculation of regurgitant variables were developed. The first method calculated peak regurgitant flow rate from CD and the second method calculated regurgitant flow volume from CW. Both methods showed excellent correlation with the corresponding true values from an electromagnetic flowmeter. The promising preliminary results in such a realistic porcine model indicate the possibility of establishing a routine procedure to be tested in the clinical setting.
URI: https://hdl.handle.net/20.500.14279/1681
ISSN: 03015629
DOI: http://dx.doi.org/10.1016/S0301-5629(98)00161-6
Rights: © 1999 World Federation for Ultrasound in Medicine & Biology
Type: Article
Affiliation: University of Alabama at Birmingham 
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations 50

8
checked on 13 Φεβ 2018

Page view(s) 50

444
Last Week
0
Last month
7
checked on 21 Μαϊ 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα