Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.14279/2937
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Constantinides, Georgios | en |
dc.contributor.author | Athanasiou, Kyriacos A. | en |
dc.contributor.author | Agarwal, Animesh | en |
dc.contributor.other | Κωνσταντινίδης, Γιώργος | - |
dc.date.accessioned | 2013-03-11T13:01:07Z | en |
dc.date.accessioned | 2013-05-17T05:34:08Z | - |
dc.date.accessioned | 2015-12-02T12:27:23Z | - |
dc.date.available | 2013-03-11T13:01:07Z | en |
dc.date.available | 2013-05-17T05:34:08Z | - |
dc.date.available | 2015-12-02T12:27:23Z | - |
dc.date.issued | 1992 | en |
dc.identifier.citation | American Society of Mechanical Engineers, Bioengineering Division (Publication) BED,1992, Volume 22, Pages 195-198 | en |
dc.identifier.isbn | 0791811166 | en |
dc.description.abstract | Using the semi-analytical/semi-numerical biphasic creep indentation methodology and a biphasic finite element/optimization procedure with experimental creep data, we obtained three material properties of articular cartilage in eight human hip osteochondral specimens. Close agreement was observed in these properties obtained with the two procedures, even though different boundary conditions are used in the two methods. Furthermore, we used a finite element/optimization procedure on various initial time intervals of the experimental creep curves to determine if it is necessary to use all data points up to equilibrium for successful evaluation of the tissue's material properties. The results suggest that, in the human femoral head, as little as the first 20 minutes of experimental creep may be needed for successful evaluation of the tissue's intrinsic mechanical properties. | en |
dc.description.uri | https://hdl.handle.net/20.500.14279/2937 | - |
dc.format | en | |
dc.language.iso | en | en |
dc.rights | © ASME. | en |
dc.subject | Biomechanics | en |
dc.subject | Finite element method | en |
dc.subject | Mathematical models | en |
dc.subject | Cartilage | en |
dc.title | Creep indentation of human hip articular cartilage: comparisons of biphasic finite element/optimization and semi-analytical solutions | en |
dc.type | Book Chapter | en |
dc.affiliation | University of Texas | en |
dc.dept.handle | 123456789/54 | en |
item.fulltext | No Fulltext | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | none | - |
item.openairecristype | http://purl.org/coar/resource_type/c_3248 | - |
item.openairetype | bookPart | - |
item.languageiso639-1 | en | - |
crisitem.author.dept | Department of Mechanical Engineering and Materials Science and Engineering | - |
crisitem.author.faculty | Faculty of Engineering and Technology | - |
crisitem.author.orcid | 0000-0003-1979-5176 | - |
crisitem.author.parentorg | Faculty of Engineering and Technology | - |
Appears in Collections: | Κεφάλαια βιβλίων/Book chapters |
CORE Recommender
Page view(s) 50
336
Last Week
2
2
Last month
8
8
checked on May 12, 2024
Google ScholarTM
Check
Altmetric
Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.