Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.14279/2921
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Giddens, Don P. | en |
dc.contributor.author | Jones, Steve A. | en |
dc.contributor.author | Anayiotos, Andreas | - |
dc.contributor.other | Αναγιωτός, Ανδρέας | - |
dc.date.accessioned | 2013-03-05T10:03:40Z | en |
dc.date.accessioned | 2013-05-17T05:34:07Z | - |
dc.date.accessioned | 2015-12-02T12:26:51Z | - |
dc.date.available | 2013-03-05T10:03:40Z | en |
dc.date.available | 2013-05-17T05:34:07Z | - |
dc.date.available | 2015-12-02T12:26:51Z | - |
dc.date.issued | 1992 | en |
dc.identifier.citation | American Society of Mechanical Engineers, Bioengineering Division (Publication) BED, 1992, Volume 22, Pages 281-284 | en |
dc.identifier.isbn | 0791811166 | en |
dc.identifier.uri | https://hdl.handle.net/20.500.14279/2921 | - |
dc.description.abstract | The flow dynamic characteristics of a compliant model of a human carotid bifurcation were investigated and compared with a rigid model of similar geometry [1,2]. Using Laser Doppler Velocimetry the flowfield was interrogated in two orthogonal planes at different locations along the axis of the internal carotid. The wall motion under physiologic pulsatile conditions was also simultaneously monitored. Complicated flow features such as helical structures and regions of reversed flow were analyzed. Negative velocity regions at the proximal axial locations were augmented temporally and spatially for the compliant model. Helical structures had different temporal characteristics and appeared more spread towards the centerline in the presence of a compliant wall. | en |
dc.format | en | |
dc.language.iso | en | en |
dc.rights | © ASME | en |
dc.subject | Hemodynamics | en |
dc.subject | Blood-vessels | en |
dc.subject | Laser Doppler velocimeter | en |
dc.title | General flow characteristics in a compliant model of a carotid bifurcation | en |
dc.type | Book Chapter | en |
dc.affiliation | University of Alabama at Birmingham | en |
dc.dept.handle | 123456789/54 | en |
item.cerifentitytype | Publications | - |
item.openairetype | bookPart | - |
item.fulltext | No Fulltext | - |
item.grantfulltext | none | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_3248 | - |
crisitem.author.dept | Department of Mechanical Engineering and Materials Science and Engineering | - |
crisitem.author.faculty | Faculty of Engineering and Technology | - |
crisitem.author.orcid | 0000-0003-4471-7604 | - |
crisitem.author.parentorg | Faculty of Engineering and Technology | - |
Appears in Collections: | Κεφάλαια βιβλίων/Book chapters |
CORE Recommender
Page view(s) 20
366
Last Week
0
0
Last month
3
3
checked on Oct 14, 2024
Google ScholarTM
Check
Altmetric
Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.