Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.14279/23598
Title: | Media and Intima Thickness and Texture Analysis of the Common Carotid Artery | Authors: | Loizou, Christos P. Pattichis, Constantinos S. Pantzaris, Marios C. |
Major Field of Science: | Engineering and Technology | Field Category: | Medical Engineering | Keywords: | Snakes;Ultrasound imaging;Media layer;Texture analysis;Common carotid artery | Issue Date: | 2012 | Source: | Ultrasound Imaging: Advances and Applications, 2012, pp. 99-128 | Start page: | 99 | End page: | 128 | Abstract: | The intima–media thickness (IMT) of the common carotid artery (CCA) is widely used as an early indicator for the development of cardiovascular disease (CVD). It was proposed but not thoroughly investigated that the media layer (ML) thickness (MLT), its composition, and texture may be indicative of cardiovascular risk and for differentiating between patients with high and low risk. In this study, we investigate an automated snakes segmentation method for segmenting the ML and the intima layer (IL) and measurement of the MLT and the intima layer thickness (ILT) in ultrasound images of the CCA. We furthermore investigate the application of texture analysis of the ML of the CCA and how texture is affected by age and gender. The snakes segmentation method was used, and was evaluated on 100 longitudinal ultrasound images acquired from asymptomatic subjects, against manual segmentation performed by a neurovascular expert. The mean ± standard deviation (sd) for the first and second sets of manual and the automated IMT, MLT, and ILT measurements were 0. 71 ± 0. 17 mm, 0. 72 ± 0. 17 mm, 0. 67 ±0. 2 mm, 0. 25 ± 0. 12 mm, 0. 27 ± 0. 14, and 0. 25 ± 0. 11 mm; and 0. 43 ±0. 10 mm, 0. 44 ± 0. 13 mm, and 0. 42 ± 0. 10 mm, respectively. There was overall no significant difference between the manual and the automated IMC, ML, and IL segmentation measurements. Therefore, the automated segmentation method proposed in this study may be used successfully in the measurement of the MLT and ILT complementing the manual measurements. MLT was also shown to increase with age (for both the manual and the automated measurements). Following the segmentation of the three structures, we also investigated the application of texture analysis of the ML of the CCA and how texture is affected by age and gender. The 100 images were separated into three different age groups, namely below 50, between 50 and 60, and above 60 years old. Furthermore, the images were separated according to gender. A total of 61 different texture features were extracted from the intima layer (IL), the ML, and the intima–media complex (IMC). We have found that male patients tended to have larger media layer thickness (MLT) values as compared to the MLT of female patients of the same age. We have also found significant differences among texture features extracted from the IL, ML, and IMC from different age groups. Furthermore, for some texture features, we found that they follow trends that correlate with a patient’s age. For example, the gray-scale median GSM of the ML falls linearly with increasing MLT and with increasing age. Our findings suggest that ultrasound image texture analysis of the media layer has potential as an assessment biomarker for the risk of stroke. | URI: | https://hdl.handle.net/20.500.14279/23598 | ISBN: | 978-1-4614-1180-2 | DOI: | 10.1007/978-1-4614-1180-2_5 | Rights: | © Springer | Type: | Book Chapter | Affiliation : | Intercollege Cyprus Institute of Neurology and Genetics University of Cyprus |
Publication Type: | Peer Reviewed |
Appears in Collections: | Κεφάλαια βιβλίων/Book chapters |
CORE Recommender
This item is licensed under a Creative Commons License