Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/1852
Τίτλος: Probing mechanical properties of fully hydrated gels and biological tissues
Συγγραφείς: Constantinides, Georgios 
Kalcioglua, Z. Ilke 
McFarlanda, Meredith 
Smithc, James F. 
Vliet, Krystyn J. Van 
Major Field of Science: Engineering and Technology
Field Category: Other Engineering and Technologies
Λέξεις-κλειδιά: Mechanical properties;Indentation;Hydrated tissues;Elasticity;Hydrogels
Ημερομηνία Έκδοσης: 2008
Πηγή: Journal of biomechanics, 2008, vol. 41, no. 15, pp. 3285-3289
Volume: 41
Issue: 15
Start page: 3285
End page: 3289
Περιοδικό: Journal of Biomechanics 
Περίληψη: A longstanding challenge in accurate mechanical characterization of engineered and biological tissues is maintenance of both stable sample hydration and high instrument signal resolution. Here, we describe the modification of an instrumented indenter to accommodate nanomechanical characterization of biological and synthetic tissues in liquid media, and demonstrate accurate acquisition of force–displacement data that can be used to extract viscoelastoplastic properties of hydrated gels and tissues. We demonstrate the validity of this approach via elastoplastic analysis of relatively stiff, water-insensitive materials of elastic moduli E>1000kPa (borosilicate glass and polypropylene), and then consider the viscoelastic response and representative mechanical properties of compliant, synthetic polymer hydrogels (polyacrylamide-based hydrogels of varying mol%-bis crosslinker) and biological tissues (porcine skin and liver) of E<500kPa. Indentation responses obtained via loading/unloading hystereses and contact creep loading were highly repeatable, and the inferred E were in good agreement with available macroscopic data for all samples. As expected, increased chemical crosslinking of polyacrylamide increased stiffness (E40kPa) and decreased creep compliance. E of porcine liver (760kPa) and skin (222kPa) were also within the range of macroscopic measurements reported for a limited subset of species and disease states. These data show that instrumented indentation of fully immersed samples can be reliably applied for materials spanning several orders of magnitude in stiffness (E=kPa–GPa). These capabilities are particularly important to materials design and characterization of macromolecules, cells, explanted tissues, and synthetic extracellular matrices as a function of spatial position, degree of hydration, or hydrolytic/enzymatic/corrosion reaction times.
URI: https://hdl.handle.net/20.500.14279/1852
ISSN: 00219290
DOI: 10.1016/j.jbiomech.2008.08.015
Rights: © Elsevier
Type: Article
Affiliation: Massachusetts Institute of Technology 
Micro Materials Ltd 
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

80
checked on 9 Νοε 2023

WEB OF SCIENCETM
Citations 50

74
Last Week
0
Last month
0
checked on 29 Οκτ 2023

Page view(s)

444
Last Week
3
Last month
11
checked on 17 Μαϊ 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα