Τίτλος: Experimental validation of a CFD model for spiral Ground Heat Exchangers
Συγγραφείς: Aresti, Lazaros 
Florides, Georgios A. 
Christodoulides, Paul 
Major Field of Science: Engineering and Technology
Field Category: Electrical Engineering - Electronic Engineering - Information Engineering
Λέξεις-κλειδιά: Hydroelectricity, Geothermal & Solar Energy
Ημερομηνία Έκδοσης: 2019
Πηγή: 6th International Conference on Energy, Sustainability and Climate Change ESCC2019
Conference: International Conference on Energy Sustainability and Climate Change 
Περίληψη: With the recent advancement of Renewable Energy Systems, one such expression – Shallow Geothermal Energy – frequently finds application in the form of Ground Source Heat Pumps (GSHPs). GSHP systems are used for space heating and cooling via tubes directed into the ground. Vertical Ground (or Borehole) Heat Exchangers (GHEs) with different configurations (mainly of U-tube, double U-tube type) extract or reject heat into the ground. Spiral or Helical type GHEs have been introduced as an alternative to reduce the depth and hence the cost of GSHP systems. It was only recently that such GHEs have been used in the foundation piles, identified as Energy Piles. Energy piles are reinforced concrete foundations with helical pipes whereby the buildings foundations are utilized to provide space heating and cooling. In general, the sheer experimental set-up and testing of a GHE is expensive and time consuming, therefore computational investigation is preferable. To this end the current paper introduces a three-dimensional mathematical model using the COMSOL Multiphysics software, based on the convection-diffusion equation. The related parameters are adjusted to present actual parameters taken from experimental data. Hence, the computational model is validated against available experimental data. The validated model is subsequently adapted to match the Mediterranean conditions in Cyprus. An investigation of the important implications of the design of GHEs, such as variable pitch length and spiral tube length is also conducted.
URI: https://hdl.handle.net/20.500.14279/15747
Type: Conference Papers
Affiliation: Cyprus University of Technology 
Εμφανίζεται στις συλλογές:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation

Αρχεία σε αυτό το τεκμήριο:
Αρχείο Περιγραφή ΜέγεθοςΜορφότυπος
ESCC2019 Abstract PC.pdf85.82 kBAdobe PDFΔείτε/ Ανοίξτε
CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

Page view(s) 50

273
Last Week
3
Last month
8
checked on 18 Μαϊ 2024

Download(s) 50

41
checked on 18 Μαϊ 2024

Google ScholarTM

Check


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα