Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/1399
Τίτλος: Inter-comparison of lidar and ceilometer retrievals for aerosol and planetary boundary layer profiling over Athens, Greece
Συγγραφείς: Tsaknakis, Georgios 
Papayannis, Alexandros D. 
Mamouri, Rodanthi-Elisavet 
Kokkalis, Panagiotis 
Amiridis, Vassilis 
Kambezidis, Harry D. 
Georgoussis, Georgios 
Avdikos, Georgios K. 
Major Field of Science: Engineering and Technology
Field Category: Computer and Information Sciences;ENGINEERING AND TECHNOLOGY
Λέξεις-κλειδιά: Cloud Height Indicator;Troposphere;Convective Boundary Layer
Ημερομηνία Έκδοσης: Ιου-2011
Πηγή: Atmospheric Measurement Techniques, 2011, vol. 4, no. 6, pp. 1261-1273
Volume: 4
Issue: 6
Start page: 1261
End page: 1273
Περιοδικό: Atmospheric Measurement Techniques 
Περίληψη: This study presents an inter-comparison of two active remote sensors (lidar and ceilometer) to determine the mixing layer height and structure of the Planetary Boundary Layer (PBL) and to retrieve tropospheric aerosol vertical profiles over Athens, Greece. This inter-comparison was performed under various strongly different aerosol loads/types (urban air pollution, biomass burning and Saharan dust event), implementing two different lidar systems (one portable Raymetrics S.A. lidar system running at 355 nm and one multi-wavelength Raman lidar system running at 355 nm, 532 nm and 1064 nm) and one CL31 Vaisala S.A. ceilometer (running at 910 nm). Spectral conversions of the ceilometer's data were performed using the Ångström exponent estimated by ultraviolet multi-filter radiometer (UV-MFR) measurements. The inter-comparison was based on two parameters: the mixing layer height determined by the presence of the suspended aerosols and the attenuated backscatter coefficient. Additionally, radiosonde data were used to derive the PBL height. In general, a good agreement was found between the ceilometer and the lidar techniques in both inter-compared parameters in the height range from 500 m to 5000 m, while the limitations of each instrument are also examined.
URI: https://hdl.handle.net/20.500.14279/1399
ISSN: 18678548
DOI: 10.5194/amt-4-1261-2011
Rights: © Author(s) CC Attribution 3.0 License
Type: Article
Affiliation: National Technical University Of Athens 
Affiliation: National Technical University Of Athens 
National Observatory of Athens 
Raymetrics S.A 
Εμφανίζεται στις συλλογές:Άρθρα/Articles

Αρχεία σε αυτό το τεκμήριο:
Αρχείο Περιγραφή ΜέγεθοςΜορφότυπος
Inter comparison of lidar and celiometer retrievals for aerosol and planetary.pdf2.92 MBAdobe PDFΔείτε/ Ανοίξτε
CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

81
checked on 9 Νοε 2023

WEB OF SCIENCETM
Citations

82
Last Week
0
Last month
1
checked on 29 Οκτ 2023

Page view(s) 10

492
Last Week
1
Last month
9
checked on 13 Μαϊ 2024

Download(s)

338
checked on 13 Μαϊ 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα