Τίτλος: | Inter-comparison of lidar and ceilometer retrievals for aerosol and planetary boundary layer profiling over Athens, Greece | Συγγραφείς: | Tsaknakis, Georgios Papayannis, Alexandros D. Mamouri, Rodanthi-Elisavet Kokkalis, Panagiotis Amiridis, Vassilis Kambezidis, Harry D. Georgoussis, Georgios Avdikos, Georgios K. |
Major Field of Science: | Engineering and Technology | Field Category: | Computer and Information Sciences;ENGINEERING AND TECHNOLOGY | Λέξεις-κλειδιά: | Cloud Height Indicator;Troposphere;Convective Boundary Layer | Ημερομηνία Έκδοσης: | Ιου-2011 | Πηγή: | Atmospheric Measurement Techniques, 2011, vol. 4, no. 6, pp. 1261-1273 | Volume: | 4 | Issue: | 6 | Start page: | 1261 | End page: | 1273 | Περιοδικό: | Atmospheric Measurement Techniques | Περίληψη: | This study presents an inter-comparison of two active remote sensors (lidar and ceilometer) to determine the mixing layer height and structure of the Planetary Boundary Layer (PBL) and to retrieve tropospheric aerosol vertical profiles over Athens, Greece. This inter-comparison was performed under various strongly different aerosol loads/types (urban air pollution, biomass burning and Saharan dust event), implementing two different lidar systems (one portable Raymetrics S.A. lidar system running at 355 nm and one multi-wavelength Raman lidar system running at 355 nm, 532 nm and 1064 nm) and one CL31 Vaisala S.A. ceilometer (running at 910 nm). Spectral conversions of the ceilometer's data were performed using the Ångström exponent estimated by ultraviolet multi-filter radiometer (UV-MFR) measurements. The inter-comparison was based on two parameters: the mixing layer height determined by the presence of the suspended aerosols and the attenuated backscatter coefficient. Additionally, radiosonde data were used to derive the PBL height. In general, a good agreement was found between the ceilometer and the lidar techniques in both inter-compared parameters in the height range from 500 m to 5000 m, while the limitations of each instrument are also examined. | URI: | https://hdl.handle.net/20.500.14279/1399 | ISSN: | 18678548 | DOI: | 10.5194/amt-4-1261-2011 | Rights: | © Author(s) CC Attribution 3.0 License | Type: | Article | Affiliation: | National Technical University Of Athens | Affiliation: | National Technical University Of Athens National Observatory of Athens Raymetrics S.A |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
Αρχεία σε αυτό το τεκμήριο:
Αρχείο | Περιγραφή | Μέγεθος | Μορφότυπος | |
---|---|---|---|---|
Inter comparison of lidar and celiometer retrievals for aerosol and planetary.pdf | 2.92 MB | Adobe PDF | Δείτε/ Ανοίξτε |
CORE Recommender
SCOPUSTM
Citations
81
checked on 9 Νοε 2023
WEB OF SCIENCETM
Citations
82
Last Week
0
0
Last month
1
1
checked on 29 Οκτ 2023
Page view(s) 10
492
Last Week
1
1
Last month
9
9
checked on 13 Μαϊ 2024
Download(s)
338
checked on 13 Μαϊ 2024
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα