Τίτλος: | L-band CYTOP Bragg gratings for ultrasound sensing | Συγγραφείς: | Broadway, Christian Kalli, Kyriacos Theodosiou, Antreas Zubel, Michal Sugden, Kate Megret, Patrice Caucheteur, Christophe |
Major Field of Science: | Engineering and Technology | Field Category: | Materials Engineering | Λέξεις-κλειδιά: | Biomedical applications;CYTOP;Fibre Bragg gratings;Fibre sensors;Polymer optical fibre;Ultrasound detection | Ημερομηνία Έκδοσης: | 25-Απρ-2018 | Πηγή: | Proceedings of SPIE - The International Society for Optical Engineering, 10681, art. no. 1068109; Micro-Structured and Specialty Optical Fibres V, 2018, 25-26 April, Strasbourg, France | Conference: | Micro-Structured and Specialty Optical Fibres V | Περίληψη: | Polymer optical fibre (POF) has been receiving increasing attention for sensing applications. The fundamental properties of POF such as PMMA deliver at least an order of magnitude in improvements over silica fibres, though practical difficulties create additional complexity. POF has the potential to deliver lower acoustic impedance, a reduced Young's Modulus and a higher acoustic sensitivity within the megahertz region. In contrast, existing piezo-electric transducers have an inherent narrow acoustic bandwidth and a proportionality to size that causes difficulties for applications such as endoscopy within the biomedical domain. POF generally suffers high attenuation per kilometre at telecommunications wavelengths, limiting fibre lengths to mere centimetres. However, CYTOP, a graded index perfluorinated polymer, is a commercially certified product allowing the use of telecoms region technology and tens of meters of fibre without exceeding acceptable losses. With an effective refractive index between 1.32 and 1.33, it is fundamentally better placed for applications using water or a similar media for acoustic coupling. We demonstrate ultrasonic detection at 5,10 and 15 MHz using a TFBG within a CYTOP fibre in the telecoms region and the latest knowledge in POF handling and connectorisation. This first step in the use of CYTOP demonstrates the viability of the sensor and paves the way towards further advances towards its eventual application. | ISBN: | 978-151061888-6 | ISSN: | 0277-786X | DOI: | 10.1117/12.2307129 | Rights: | © 2018 SPIE. | Type: | Conference Papers | Affiliation: | University of Mons Cyprus University of Technology Aston University |
Εμφανίζεται στις συλλογές: | Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation |
CORE Recommender
SCOPUSTM
Citations
50
9
checked on 6 Νοε 2023
Page view(s) 50
300
Last Week
3
3
Last month
10
10
checked on 11 Μαϊ 2024
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα