Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/1298
Τίτλος: Degradation of microcystin-lr using sulfate radicals generated through photolysis, thermolysis and e- transfer mechanisms
Συγγραφείς: De La Cruz, Armah A. 
Dionysiou, Dionysios Demetriou D. 
Antoniou, Maria G. 
Major Field of Science: Agricultural Sciences
Field Category: Chemical Engineering
Λέξεις-κλειδιά: Cyanotoxins;e- transfer mechanisms;Fenton Reagent;Hydrogen peroxide;Microcystin-LR;Oxidants;Peroxymonosulfate;Persulfate;Photolysis;Sulfate radicals;Thermolysis
Ημερομηνία Έκδοσης: 7-Ιου-2010
Πηγή: Applied Catalysis B: Environmental, 2010, vol. 96, no. 3-4, pp. 290-298
Volume: 96
Issue: 3-4
Start page: 290
End page: 298
Περιοδικό: Applied Catalysis B: Environmental 
Περίληψη: This study explores the potential use of sulfate radical-based advanced oxidation technologies (SR-AOTs) for the degradation of the naturally occurring hepatotoxin, microcystin-LR (MC-LR). The generation of sulfate radicals was achieved by activation of the oxidants persulfate (PS) and peroxymonosulfate (PMS) through electrophilic transition metal cations (Ag+ and Co2+, respectively), radiation (UV 300 < λ < 400 nm) and/or heat (T = 30 °C). These systems were compared to more frequently used AOTs systems in industrial applications; the Fenton Reagent (FR) and hydrogen peroxide coupled with heat and radiation. Even though SO4{radical dot}- has similar redox potential to hydroxyl radical (HO{radical dot}), to the best of our knowledge, SR-AOTs have not been tested for the degradation of cyanotoxins. In this study, PMS was activated very efficiently with Co2+ at neutral pH and increasing catalyst concentration resulted in dramatic increase of the initial rates of degradation that reached a plateau for CCo(II) ≥ 1 mg. Based on the optimum pH conditions for each system, the efficiency order is Co2+/PMS > Fe2+/H2O2 ≫ Ag+/PS, which we believe is associated with the energy of the lower unoccupied molecular orbital of the oxidants. When UV (300 < λ < 400 nm) radiation was used, the PS system was more efficient than PMS and H2O2 at all different oxidant concentrations. Since, the UV lamps used in the study emit light at a range of wavelengths (300 < λ < 400 nm), the activation of the oxidants is believed to be caused by the emission spectra and not just λmax = 365 nm. At acidic conditions, the PS/UV (300 < λ < 400 nm)/pH 3 and PMS/UV/pH 3 systems were most efficient and required the least amount of energy to reduce the toxin concentration by one order of magnitude. When thermal activation was used, PMS yielded the highest degradation efficiency (∼77%) compared to 52% for the PS and less then 2.5% for H2O2.
URI: https://hdl.handle.net/20.500.14279/1298
ISSN: 9263373
DOI: 10.1016/j.apcatb.2010.02.013
Rights: © Elsevier
Type: Article
Affiliation: University of Cincinnati 
Affiliation: University of Cincinnati 
U.S. Environmental Protection Agency 
Cyprus University of Technology 
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

540
checked on 9 Νοε 2023

WEB OF SCIENCETM
Citations 50

496
Last Week
0
Last month
2
checked on 29 Οκτ 2023

Page view(s) 5

706
Last Week
4
Last month
11
checked on 11 Μαϊ 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα