Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/1702
DC FieldValueLanguage
dc.contributor.authorLi, Longchuan-
dc.contributor.authorDoyle, Mark W.-
dc.contributor.authorAnayiotos, Andreas-
dc.contributor.otherΑναγιωτός, Ανδρέας-
dc.date.accessioned2013-03-04T13:54:26Zen
dc.date.accessioned2013-05-17T05:22:17Z-
dc.date.accessioned2015-12-02T09:59:48Z-
dc.date.available2013-03-04T13:54:26Zen
dc.date.available2013-05-17T05:22:17Z-
dc.date.available2015-12-02T09:59:48Z-
dc.date.issued2007-08-29-
dc.identifier.citationJournal of Magnetic Resonance Imaging, 2007, vol. 26, no. 3, pp. 805-815.en_US
dc.identifier.issn10531807-
dc.identifier.urihttps://hdl.handle.net/20.500.14279/1702-
dc.description.abstractPurpose: To test the potential of a phase contrast magnetic resonance (PC-MR) sparse sampling technique, fragmented regional interpolation segmentation for k-space (FRISK), to capture complex flow features within a breathhold duration by using numerical simulations and experimental approaches. Materials and Methods: Computational fluid dynamics (CFD) data of three models were generated: a two-chamber orifice flow model simulating valvular regurgitation, a femoral artery model, and a U-shaped model simulating the aortic arch. These data were used to simulate conventional and FRISK PC-MR data acquisitions. FRISK parameters can be adapted for different flow fields to capture either high temporal information or complexly varying spatial information with a temporal component or a mixture of both. In vivo PC-MR images on a healthy volunteer were sampled to compare conventional PC-MR with novel FRISK imaging. Results: In our simulations of three representative models, when only the errors from different sampling sequences were considered, FRISK was shown to maintain or even improve data accuracy while cutting the scan time by at least 50% compared to corresponding conventional PC-MR. By adapting the FRISK parameters for flowfields with different features, FRISK was capable of capturing in-plane and through-plane velocity information with excellent detail in approximately 20 heartbeats breathhold duration. The results of the in vivo MR experiment were consistent with the simulation results, showing that breathhold FRISK imaging improved spatial resolution of the data and maintained adequate temporal resolution compared with breathhold conventional imaging. Conclusion: FRISK, a new MRI sampling sequence that sparsely samples data and aligns acquired data during postprocessing, provides a scan time advantage of approximately a factor of 2 compared to conventional scans, and allowed rapid or breathhold scanning while obtaining acceptable accuracy.en_US
dc.formatpdfen_US
dc.language.isoenen_US
dc.relation.ispartofJournal of Magnetic Resonance Imagingen_US
dc.rights© Wileyen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subjectHeart Imagingen_US
dc.subjectk-spacesen_US
dc.subjectComputational fluid dynamicsen_US
dc.titleNumerical simulation of in vitro pulsatile flow and its study using FRISK, a rapid phase contrast techniqueen_US
dc.typeArticleen_US
dc.affiliationUniversity of Alabama at Birminghamen
dc.collaborationUniversity of Alabama at Birminghamen_US
dc.journalsOpen Accessen_US
dc.countryUnited Statesen_US
dc.subject.fieldEngineering and Technologyen_US
dc.publicationPeer Revieweden_US
dc.identifier.doi10.1002/jmri.21003en_US
dc.dept.handle123456789/54en
dc.relation.issue3en_US
dc.relation.volume26en_US
cut.common.academicyear2006-2007en_US
dc.identifier.spage805en_US
dc.identifier.epage815en_US
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
item.openairetypearticle-
item.grantfulltextnone-
item.languageiso639-1en-
item.cerifentitytypePublications-
crisitem.journal.journalissn1522-2586-
crisitem.journal.publisherWiley-
crisitem.author.deptDepartment of Mechanical Engineering and Materials Science and Engineering-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.orcid0000-0003-4471-7604-
crisitem.author.parentorgFaculty of Engineering and Technology-
Appears in Collections:Άρθρα/Articles
CORE Recommender
Show simple item record

SCOPUSTM   
Citations

1
checked on Nov 9, 2023

WEB OF SCIENCETM
Citations

1
Last Week
0
Last month
0
checked on Oct 29, 2023

Page view(s) 10

584
Last Week
4
Last month
4
checked on Feb 11, 2025

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons