Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/9504
Πεδίο DCΤιμήΓλώσσα
dc.contributor.authorXeni, Flouris-
dc.contributor.authorEleftheriou, Polyvios-
dc.contributor.authorMichaelides, Ioannis-
dc.contributor.authorHadjiyiannis, Stavros-
dc.contributor.authorPhilimis, Panayiotis-
dc.contributor.authorStylianou, Α.-
dc.contributor.otherΞενή, Φλουρής-
dc.contributor.otherΜιχαηλίδης, Ιωάννης-
dc.contributor.otherΕλευθερίου, Πολύβιος-
dc.date.accessioned2017-02-06T12:50:23Z-
dc.date.available2017-02-06T12:50:23Z-
dc.date.issued2015-01-01-
dc.identifier.citationInternational Journal of Sustainable Energy Volume 34, Issue 3-4, 21 April 2015, Pages 211-220en_US
dc.identifier.issn14786451-
dc.identifier.urihttps://hdl.handle.net/20.500.14279/9504-
dc.description.abstractThe present work aims to establish the thermal characteristics and actual thermal behaviour of typical residential houses in Cyprus under real weather conditions. For this purpose, a wireless web-based monitoring system has been deployed covering 44 different houses, geographically spread all over Cyprus. Construction materials varied amongst each house, resulting in a theoretical U-value range of 0.467–1.389 W/m<sup>2</sup> K. Calibrated temperature sensors were installed and measurements were conducted at 30-min intervals for each individual house. The indoor air temperature of each house, the outside (ambient) air temperature, and the internal and external wall surface temperatures have continuously been monitored for a period of 15 months. Processing the above-mentioned data has led to the establishment of the mean indoor air temperature of the typical Cypriot residence and calculation of the U-value for each individual wall, facing north, south, east and west, including the roof, comprising the building envelope. Variations of the calculated U-value of up to 25% for each wall orientation were observed, even though construction materials of each wall remain the same. Furthermore, deviations of up to 30% from the theoretical U-value calculation were also observed.en_US
dc.formatpdfen_US
dc.language.isoenen_US
dc.rights© 2014 Taylor & Francis.en_US
dc.subjectBuilding envelopeen_US
dc.subjectEnergyen_US
dc.subjectHeat lossesen_US
dc.subjectU-valueen_US
dc.titleIn situ U-value measurements for today's Cypriot housesen_US
dc.typeArticleen_US
dc.doi10.1080/14786451.2014.882334en_US
dc.collaborationCyprus University of Technologyen_US
dc.subject.categoryMechanical Engineeringen_US
dc.journalsSubscription Journalen_US
dc.countryCyprusen_US
dc.subject.fieldEngineering and Technologyen_US
dc.publicationPeer Revieweden_US
item.fulltextNo Fulltext-
item.cerifentitytypePublications-
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
item.openairetypearticle-
item.languageiso639-1en-
crisitem.author.deptDepartment of Mechanical Engineering and Materials Science and Engineering-
crisitem.author.deptDepartment of Mechanical Engineering and Materials Science and Engineering-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.orcid0000-0002-7542-9237-
crisitem.author.parentorgFaculty of Engineering and Technology-
crisitem.author.parentorgFaculty of Engineering and Technology-
Εμφανίζεται στις συλλογές:Άρθρα/Articles
CORE Recommender
Δείξε τη σύντομη περιγραφή του τεκμηρίου

Page view(s) 50

389
Last Week
3
Last month
11
checked on 17 Μαϊ 2024

Google ScholarTM

Check


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα