Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/11025
Title: A cognitive monitoring system for detecting and isolating contaminants and faults in intelligent buildings
Authors: Boracchi, Giacomo Mo 
Michaelides, Michalis P. 
Roveri, Manuel 
Major Field of Science: Engineering and Technology
Field Category: Electrical Engineering - Electronic Engineering - Information Engineering
Keywords: Change detection tests;Change point methods;Chemical and biological sensors;Cognitive monitoring system;Contaminants detection;Fault detection;Gas detectors;Hierarchical system;Indoor air quality;Intelligent buildings;Isolation and identification algorithms;Sensor faults
Issue Date: Mar-2018
Source: IEEE Transactions on Systems, Man, and Cybernetics: Systems, 2018, vol. 48, no. 3, pp. 433 - 447
Volume: 48
Issue: 3
Start page: 433
End page: 447
Journal: IEEE Transactions on Systems, Man, and Cybernetics: Systems 
Abstract: Intelligent buildings are typically endowed with sensing devices that are able to measure the concentration of specific contaminants in relevant zones. The collected measurements are subsequently processed by intelligent algorithms in order to enable the prompt detection and isolation of contaminant sources inside the building. Unfortunately, in real-world conditions, these sensing devices may suffer from faults affecting the sensors or the embedded electronics. Such faults, generally result in perturbed or missed data in the acquired data-stream, that can induce false alarms (or possibly missed alarms) and compromise the contaminant detection and isolation ability. This paper proposes a three-layer cognitive monitoring system for the detection and isolation of both contaminants and sensor faults in intelligent buildings. The first two layers are designed for the prompt detection of small variations in the concentration of a specific contaminant, while reducing the possible occurrence of false alarms. At the third layer, a cognitive mechanism employing a propagation model for the contaminant, which is based on the airflows between the building zones, allows to isolate the source zone and discriminate between sensor faults and the presence of a contaminant source. The proposed method is validated using a realistic 14-zone building scenario.
URI: https://hdl.handle.net/20.500.14279/11025
ISSN: 21682216
DOI: 10.1109/TSMC.2016.2608419
Rights: © IEEE
Type: Article
Affiliation : Politecnico di Milano 
Cyprus University of Technology 
Appears in Collections:Άρθρα/Articles

CORE Recommender
Show full item record

SCOPUSTM   
Citations

9
checked on Nov 9, 2023

WEB OF SCIENCETM
Citations 20

8
Last Week
0
Last month
0
checked on Oct 31, 2023

Page view(s) 20

434
Last Week
2
Last month
26
checked on Apr 30, 2024

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.