Title: Shear stress at a compliant model of the human carotid bifurcation
Authors: Jones, Steve A. 
Giddens, Don P. 
Anayiotos, Andreas 
Keywords: Cardiovascular system
Transducers
Hemodynamics
Blood
Issue Date: 1994
Publisher: ASME
Source: Journal of Biomechanical Engineering, 1994, Volume 116, Issue 1, Pages 98-106
Abstract: To investigate the role of a compliant wall to the near wall hemodynamic flowfield, two models of the carotid bifurcation were constructed. Both were of identical internal geometries, however, one was made of compliant material which produced approximately the same degree of wall motion as that occurring in vivo while the other one was rigid. The inner geometries were formed from the same mold so that the configurations are directly comparable. Each model was placed in a pulsatile flow system that produced a physiologic flow waveform. Velocity was measured with a single component Laser system and wall shear rate was estimated from near wall data. Wall motion in the compliant model was measured by a wall motion transducer and the maximum diameter change varied between 4-7 percent in the model with the greatest change at the axis intersection. The mean shear stress in the compliant model was observed to be smaller by about 30 percent at most locations. The variation in peak shear stress was greater and occasionally reached as much as 100 percent with the compliant model consistently having smaller positive and negative peaks. The separation point was seen to move further upstream in the compliant cast. The modified flowfield in the presence of a compliant wall can then be important in the hemodynamic theory of atherogenesis. To investigate the role of a compliant wall to the near wall hemodynamic flowfield, two models of the carotid bifurcation were constructed. Both were of identical internal geometries, however, one was made of compliant materials which produced approximately the same degree of wall motion as that occurring in vivo while the other one was rigid. The inner geometries were formed from the same mold so that the configurations are directly comparable. Each model was placed in a pulsatile flow system that produced a physiologic flow waveform. Velocity was measured with a single component Laser system and wall shear rate was estimated from near wall data. Wall motion in the compliant model was measured by a wall motion transducer and the maximum diameter change varied between 4-7 percent in the model with the greatest change at the axis intersection. The mean shear stress in the compliant model was observed to be smaller by about 30 percent at most locations. The variation in peak shear stress was greater and occasionally reached as much as 100 percent with the compliant model consistently having smaller positive and negative peaks. The separation point was seen to move further upstream in the compliant cast. The modified flow field in the presence of a compliant wall can the be important in the hemodynamic theory of atherogenesis.
URI: http://ktisis.cut.ac.cy/handle/10488/7614
ISSN: 01480731
DOI: 10.1115/1.2895710
Rights: © ASME
Appears in Collections:Άρθρα/Articles

Show full item record

WEB OF SCIENCETM
Citations 5

56
checked on Dec 9, 2016

Page view(s)

3
checked on Mar 30, 2017

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.