Please use this identifier to cite or link to this item: http://ktisis.cut.ac.cy/handle/10488/7079
Title: Polymer pvf bragg grating sensors based on poly(methyl methacrylate) and tppas cyclic olefin copolymer
Authors: Kalli, Kyriacos 
Webb, David J. 
Johnson, Ian P.
Yuan, Wu 
Stefani, Alessio 
Nielsen, Kristian Fog Og
Rasmussenc, Henrik K.
Bang, Ole 
Keywords: Bragg gratings
Cadmium
Copolymers
Crystal whiskers
Esters
Fibers
Issue Date: 2011
Publisher: Spie Digital Library
Source: Proceedings of SPIE - The International Society for Optical Engineering,Volume 8073, 2011, Article number80732V
Abstract: Fibre Bragg grating (FBG) sensors have been fabricated in polymer photonic crystal fibre (PCF). Results are presented using two different types of polymer optical fibre (POF); first multimode PCF with a core diameter of 50μm based on poly(methyl methacrylate) (PMMA) and second, endlessly single mode PCF with a core diameter of 6μm based on TOPAS cyclic olefin copolymer. Bragg grating inscription was achieved using a 30mW continuous wave 325nm helium cadmium laser. Both TOPAS and PMMA fibre have a large attenuation of around 1dB/cm in the 1550nm spectral region, limiting fibre lengths to no longer than 10cm. However, both have improved attenuation of under 10dB/m in the 800nm spectral region, thus allowing for fibre lengths to be much longer. The focus of current research is to utilise the increased fibre length, widening the range of sensor applications. The Bragg wavelength shift of a grating fabricated in PMMA fibre at 827nm has been monitored whilst the POF is thermally annealed at 80 °C for 7 hours. The large length of POF enables real time monitoring of the grating, which demonstrates a permanent negative Bragg wavelength shift of 24nm during the 7 hours. This creates the possibility to manufacture multiplexed Bragg sensors in POF using a single phase mask in the UV inscription manufacturing. TOPAS holds certain advantages over PMMA including a much lower affinity for water, this should allow for the elimination of cross-sensitivity to humidity when monitoring temperature changes or axial strain, which is a significant concern when using PMMA fibre.
URI: http://ktisis.cut.ac.cy/handle/10488/7079
ISBN: 978-081948663-9
DOI: 10.1117/12.890090
Rights: © 2011 SPIE.
Appears in Collections:Κεφάλαια βιβλίων/Book chapters

Show full item record

SCOPUSTM   
Citations 20

6
checked on Jan 19, 2017

Page view(s)

12
Last Week
1
Last month
2
checked on Jun 22, 2017

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.