Title: Heat transfer and sensitivity analysis in a double pipe heat exchanger filled with porous medium
Authors: Milani Shirvan, Kamel 
Mirzakhanlari, Soroush 
Kalogirou, Soteris A. 
Öztop, Hakan F. 
Mamourian, Mojtaba 
Keywords: Response surface methodology;Sensitivity analysis;Heat exchanger effectiveness double pipe;Heat exchanger;Heat transfer;Porous medium
Category: Other Engineering and Technologies
Field: Engineering and Technology
Issue Date: 1-Nov-2017
Publisher: ELSEVIER FRANCE
Source: INTERNATIONAL JOURNAL OF THERMAL SCIENCES, Volume: 121, Pages: 124-137,2017
metadata.dc.doi: http://dx.doi.org/10.1016/j.ijthermalsci.2017.07.008
Journal: International Journal of Thermal Sciences
Abstract: In this paper, 2-D numerical investigation and sensitivity analysis are performed on heat transfer rate and heat exchanger effectiveness of a double pipe heat exchanger filled with porous medium. The Darcy -Brinkman-Forchheimer model is applied to model the flow field in the porous zone. The sensitivity analysis is performed utilizing the Response Surface Methodology. The studied parameters are: Reynolds number (50 <= Re <= 250), Darcy number (10(-5) <= Da <= 10(-3)), temperature difference between hot and cold fluids (30 <= Delta T <= 70) and the porous substrate thickness (1/3 <= delta <= 1). The obtained results showed that enhancement of the Nusselt number due to the increase in Reynolds and Darcy numbers is in the vicinity of the 77.84% for the case with delta = 2/3 and Da =10(-5) to 10(-3), and 203.25% for the case with delta =1 and Re = 50 to 250. Furthermore, increasing porous substrate thickness reduces the mean Nusselt number until delta = 2/3 and then increases it. In addition, it is found that the heat exchanger effectiveness increases with the Re number and reduces with enhancement of the Da number. The sensitivity analysis showed that the sensitivity of the mean Nusselt number to the Re and Da numbers and the porous substrate thickness is positive, while the sensitivity of the heat exchanger effectiveness to the Re number is positive but to the Da number is negative.
URI: http://ktisis.cut.ac.cy/handle/10488/10502
ISSN: 1290-0729
Rights: (C) 2017 Elsevier Masson SAS. All rights reserved.
Type: Article
Appears in Collections:Άρθρα/Articles

Show full item record

Page view(s)

11
Last Week
2
Last month
checked on Dec 13, 2017

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.